-40%

US Digital Dental X-Ray Sensor Imaging System RVG Sensor/ Mobile X-Ray Machine

$ 401.27

Availability: 21 in stock
  • Display: 1280X1024
  • Central Processor: Intel Core i3 or higher
  • MPN: WUX1180300411
  • Input power: 500mW
  • Mouse: One
  • Sensor Size: 26.5×32×11.7mm
  • Hard Disk: 80GB or higher
  • Brand: Unbranded
  • Keyboard: One
  • Operating Software: Windows 7 SP1,8,10 32/64bit
  • Total Cable Length: 3 m (sensor cable + control box cable to PC)
  • Item must be returned within: 30 Days
  • Modified Item: No
  • Country/Region of Manufacture: China
  • Restocking Fee: No
  • Custom Bundle: Yes
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • Model: VXS2121
  • Operating Voltage: 5VDC
  • USB interface: two
  • Spatial Resolution: ≥7Lp/mm
  • Condition: New
  • Internal Memory: 4GB or higher
  • Runtime: Net Framework 4.6 or higher, VC++ 2015
  • All returns accepted: Returns Accepted
  • Intended Use/Discipline: Dental Laboratory
  • Warranty: 1 Year
  • Image uniformity: ≤2%

    Description

    Features:
    The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary clinics,Sensor size Suitable for child(adult single tooth)and pets.
    Hardware Requirements:
    Central Processor: Intel Core i3 or higher
    Internal Memory: 4GB or higher
    Hard Disk: 80GB or higher
    Display: 1280X1024
    USB interface: two
    Keyboard: One
    Mouse: One
    Software Requirement
    Operating Software:Windows 7 SP1,8,10 32/64bit
    Runtime: .Net Framework 4.6 or higher, VC++ 2015
    Specification:
    Product Name: Image RVG x-ray Sensor
    Product Model:XVS2121
    Operating Voltage:5VDC
    Input power:500mW
    Spatial Resolution:≥7Lp/mm
    Low contrast resolution :Able to display holes with 1mm, 1.5mm, 2mm and
    2.5mm diameter on the 0.5mm-thick aluminium foil
    Image uniformity ≤2%
    Effective image area: 20.16*20.16mm
    Sensor Size:26.5mm×32mm×11.7mm
    Adaptor Size:60mm×40mm×29.2mm
    Total Cable Length: 3 m (sensor cable + control box cable to PC)
    Warranty:1 Year
    Accessory :
    Digital sensor: 1 Set
    USB cable :1 PCS
    U Disk: 1PCS
    Disposable protective sheath: 1 Box(500)
    silicon loop: 1 PCS
    Sensor holder: 1 PCS
    Aluminum plate:1 PCS (40*40*6mm)
    ++
    ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo, you have to wait 30 seconds before you can take a normal photo

    TECHNICAL SPECIFICATIONS

    Tube Voltage
    65kv
    Tube Current
    1mA
    Time Exposure
    0.1~~1.8s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V

    220V
    Supply Frequency
    30Hz
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 2600MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles

    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0.2-0.3
    s
    0.2-0.3
    s
    Cuspid & 1st Bicuspid
    0.3-0.4
    s
    0.3-0.4
    s
    Upper 5

    6
    0.5-0.6
    s
    0.5-0.6
    s
    Upper 7

    8
    1.3-1.8
    s
    1.2-1.5.
    s
    Lower 5

    6
    0.5-0.6
    s
    0.4-0.5
    s
    Lower 7

    8
    0.6-0.8
    s
    0.5-0.7
    s
    Packing List:
    Main machine
    1pcs
    Power line
    1pcs
    User manual
    1pcs
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube
    will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded)

    then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    Points for Attention

    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt
    After turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of filming.
    When taking pictures

    the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use

    so as not to damage the delicate component.
    If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    Product Name: Oral Endoscope
    Pixel: 100W
    Brightness adjustment: 3-speed adjustment
    Simultaneous connection terminal: 1
    Light source: 6 LED light sources
    Focus range: 10mm-20mm
    Interface:computer and android
    Lens waterproof: IPX5
    Shell material: ABS
    Feature:
    1.100W high defidition camera,720P high definition transmission;
    2.Six high bright cold light sources;
    3.Three-speed brightness adjustment;
    4.Both computers and mobile phones can be used;
    5.Daily waterproofing of the lens.
    FDA Statement
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory  agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your  status as an authorized purchaser of this item before shipping of the item.
    Seller name:DENTALBRAVO
    City,State:SHENZHEN,China
    Telephone number:0755-36925817
    System, X-Ray, Mobile
    K200976
    SR-8230, SR-8230S Portable X-Ray Unit
    892.172
    IZL
    4/13/2020
    6/10/2020
    Substantially Equivalent (SESE)
    Radiology
    Radiology
    Summary
    Traditional
    No
    No